| Equipment Model |
HSBD15K-900-60 |
| Environmental Conditions | Working Environment | -10~+60 ℃ |
| Storage Temperature | -40~+70 ℃ |
| Relative Humidity | ≤95%RH, no condensation |
| Cooling Method | Forced air cooling, intelligent speed regulation |
| Altitude | 2000m, derating use above 2000m |
| Atmospheric Pressure | 79kPa~106kPa |
| DC Bus Side Parameters | Voltage Range | 200Vdc~800Vdc |
| Current Range | ±20A |
| Rated Power | 15kW |
| User Side Parameters | Voltage Range | 30~1KVdc |
| Current Range | ±100A (positive and negative current limiting points can be set separately) |
| Rated Value | 150Vdc/100A |
| Rated Power | 15kW |
| Voltage Accuracy | ±0.05% F.S |
| Current Accuracy | ±0.05% F.S |
| Ripple Coefficient | <1%Vo |
| Load Regulation Rate | ≤±0.5% |
| Start Overshoot | ≤±1% |
| Protection Functions | DC/DC | Over/undervoltage protection, overcurrent protection, overtemperature protection, short circuit protection, reverse polarity connection protection, etc. |
| Other Parameters | Working Modes | Load mode: constant current, constant voltage, constant power, constant resistance Source mode: constant voltage bidirectional current source Battery mode: constant current charging, constant voltage constant current charging, constant current discharging |
| Current Rise Time | ≤20ms |
| Bidirectional Conversion Time | ≤20ms, seamless switching |
| Noise | ≤65dB |
| Protection Grade | IP20 (single module) |
| Communication Function | Standard RS485 (external communication), CAN (internal communication) |
| Efficiency | ≥97% |
| Auxiliary Power Supply | Single-phase 220VAC±30%; or three-phase 380VAC±30% |
| Standby Power Consumption | 10W (rated input voltage) |
| Volume (W*H*D) | 288*133*410mm |
| Weight | ≤15kg |