| Equipment Model |
TP-HSBT15K-1K-100 |
| Environmental Conditions | Working Environment | -10~+60 ℃ |
| Storage Temperature | -40~+70 ℃ |
| Relative Humidity | ≤95%RH, no condensation |
| Cooling Method | Forced air cooling, intelligent speed regulation |
| Altitude | 2000m, derating use above 2000m |
| Atmospheric Pressure | 79kPa~106kPa |
| AC Side Parameters | Input System | Three-phase four-wire (3W+PE) |
| Rated Voltage | 380Vac |
| Input Current | ≤30A |
| Voltage Range | 323Vac~456Vac (-15%~+20%) |
| Frequency Range | 45~65Hz (adaptive to 50/60Hz power grid) |
| Power Factor | ≥0.97 @20%~50%output power, nominal input voltage and frequency ≥0.99 @50%~100%output power, nominal input voltage and frequency |
| THDi | ≤3% full load ≤5% @50%~100%full load output power |
| Forward and Reverse Switching Time | ≤10ms, seamless switching |
| Maximum Static Voltage Withstood When Not Working | 600Vac |
| DC Side Parameters | Voltage Range | 30~1000Vdc |
| Current Range | ±100A |
| Rated Value | LOAD:150Vdc/100A; POWER:150V/100A |
| Rated Power | LOAD:15kW; POWER:15kW |
| Voltage Accuracy | ±0.05% F.S |
| Current Accuracy | ±0.05% F.S |
| Ripple Coefficient | <1%Vo |
| Load Regulation Rate | ≤±0.5% |
| Grid Regulation Rate | ≤±0.1% |
| Start Overshoot | ≤±1% |
| Working Modes | Load mode: constant current, constant voltage, constant power, constant resistance Source mode: constant voltage bidirectional current source Battery mode: constant current charging, constant voltage constant current charging, constant current discharging |
| Current Rise Time | ≤20ms |
| Charging and Discharging Conversion Time | ≤20ms, seamless switching |
| Protection Functions | Inverter | AC over/undervoltage, DC bus over/undervoltage, bus unbalance, over/underfrequency, AC overcurrent, AC current unbalance, overtemperature, fan fault, etc. |
| DC/DC | Over/undervoltage protection, overcurrent protection, overtemperature protection, short circuit protection, reverse polarity connection protection, etc. |
| Other Parameters | Noise | ≤65dB |
| Protection Grade | IP20 (single module) |
| Communication Function | Standard RS485 (external communication), CAN (parallel operation) |
| Start-up Time | Time delay from AC power-on to module output ≤10s |
| Efficiency | Rectifier mode: ≥92.0%, @150V, 100%load current Inverter mode: ≥93%, @150V, 100%load current |
| Auxiliary Power Supply | Single-phase 220VAC±30%; three-phase 380VAC±30% |
| Standby Power Consumption | 17W |
| Volume | 423*130*405mm |
| Weight | ≤20kg |