| Equipment Model |
TP-HSBA11K-300-50 |
| Environmental Conditions | Working Environment | -10~+55 ℃ |
| Storage Temperature | -40~+70 ℃ |
| Relative Humidity | ≤95%RH, no condensation |
| Cooling Method | Forced air cooling, intelligent speed regulation |
| Altitude | 2000m, derating use above 2000m |
| Atmospheric Pressure | 79kPa~106kPa |
| Grid-connected Side Parameters | Input System | Single-phase |
| Rated Voltage | 220Vac |
| Input Current | ≤53A |
| Voltage Range | 176Vac~264Vac (-10%~+20%) |
| Frequency Range | 45~65Hz (adaptive to 50/60Hz power grid) |
| Power Factor | ≥0.97 @20%~50%output power, nominal input voltage and frequency ≥0.99 @50%~100%output power, nominal input voltage and frequency |
| THDi | ≤3% full load ≤5% @25%~100%full load output power |
| Maximum Static Voltage Withstood When Not Working | 600Vac |
| User Side Parameters | Voltage Range | Load mode: 50~300Vac Source mode: 50~300Vac Resolution: 0.1V |
| Frequency Range | Load mode: 45~65Hz Resolution: 0.01Hz Source mode: 40~70Hz Resolution: 0.01Hz |
| Current Range | 0.5-50A |
| Rated Power | LOAD:11kW; POWER:11kW |
| Voltage Accuracy | 0.1% F.S (Power mode) |
| Current Accuracy | 0.5% F.S |
| Load Regulation Rate | ≤0.5% |
| Grid Regulation Rate | ≤0.1% |
| Working Modes | Load mode: constant current, constant power, constant resistance Source mode: constant voltage bidirectional current source |
| Protection Functions | Grid Side | AC over/undervoltage, DC bus over/undervoltage, AC voltage over/underfrequency, AC overcurrent, overtemperature, fan fault, etc. |
| User Side | AC over/undervoltage, DC bus over/undervoltage, AC voltage over/underfrequency, AC overcurrent, overtemperature, etc. |
| Other Parameters | Noise | ≤65dB |
| Protection Grade | IP20 (single module) |
| Communication Function | Standard RS485 (external communication), CAN (reserved) |
| Start-up Time | Time delay from AC power-on to module output ≤10s |
| Efficiency | Rectifier mode: ≥92.0%, @230V, 25A load Inverter mode: ≥92%, @230V, 25A load |
| Standby Power Consumption | 16.5W |
| Volume | 445*88*560mm |
| Weight | ≤22kg |
| Safety Characteristics | Safety Specification Standards | IEC 61010-1:2010 IEC 61010-1:2010/AMD1:2016 |
| EMC Characteristic Standards | EN IEC61000-6-2:2019 EN IEC61000-6-4:2019 |
| Leakage Current | Leakage current ≤3.5mA |
| Insulation Resistance | Insulation resistance between DC part, AC part and shell, and between AC part and DC part ≥10MΩ |